Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography


Autoria(s): Jöres, Andreas; Heverhagen, Johannes; Bonel, Harald Marcel; Exadaktylos, Aristomenis; Klink, T
Data(s)

01/02/2016

Resumo

Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.

Formato

application/pdf

Identificador

http://boris.unibe.ch/79083/1/s-0041-107199.pdf

Jöres, Andreas; Heverhagen, Johannes; Bonel, Harald Marcel; Exadaktylos, Aristomenis; Klink, T (2016). Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. RöFo. Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 188(2), pp. 163-171. Thieme 10.1055/s-0041-107199 <http://dx.doi.org/10.1055/s-0041-107199>

doi:10.7892/boris.79083

info:doi:10.1055/s-0041-107199

info:pmid:26529263

urn:issn:1438-9029

Idioma(s)

eng

Publicador

Thieme

Relação

http://boris.unibe.ch/79083/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Jöres, Andreas; Heverhagen, Johannes; Bonel, Harald Marcel; Exadaktylos, Aristomenis; Klink, T (2016). Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. RöFo. Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren, 188(2), pp. 163-171. Thieme 10.1055/s-0041-107199 <http://dx.doi.org/10.1055/s-0041-107199>

Palavras-Chave #610 Medicine & health
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed