Clinical Outcomes According to Diabetic Status in Patients Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents: Prespecified Subgroup Analysis of the BIOSCIENCE Trial.


Autoria(s): Franzone, Anna; Pilgrim, Thomas; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Räber, Lorenz; Stortecky, Stefan; Wenaweser, Peter Martin; Jüni, Peter; Windecker, Stephan
Data(s)

01/07/2015

Resumo

BACKGROUND Ultrathin strut biodegradable polymer sirolimus-eluting stents (BP-SES) proved noninferior to durable polymer everolimus-eluting stents (DP-EES) for a composite clinical end point in a population with minimal exclusion criteria. We performed a prespecified subgroup analysis of the Ultrathin Strut Biodegradable Polymer Sirolimus-Eluting Stent Versus Durable Polymer Everolimus-Eluting Stent for Percutaneous Coronary Revascularisation (BIOSCIENCE) trial to compare the performance of BP-SES and DP-EES in patients with diabetes mellitus. METHODS AND RESULTS BIOSCIENCE trial was an investigator-initiated, single-blind, multicentre, randomized, noninferiority trial comparing BP-SES versus DP-EES. The primary end point, target lesion failure, was a composite of cardiac death, target-vessel myocardial infarction, and clinically indicated target lesion revascularization within 12 months. Among a total of 2119 patients enrolled between February 2012 and May 2013, 486 (22.9%) had diabetes mellitus. Overall diabetic patients experienced a significantly higher risk of target lesion failure compared with patients without diabetes mellitus (10.1% versus 5.7%; hazard ratio [HR], 1.80; 95% confidence interval [CI], 1.27-2.56; P=0.001). At 1 year, there were no differences between BP-SES versus DP-EES in terms of the primary end point in both diabetic (10.9% versus 9.3%; HR, 1.19; 95% CI, 0.67-2.10; P=0.56) and nondiabetic patients (5.3% versus 6.0%; HR, 0.88; 95% CI, 0.58-1.33; P=0.55). Similarly, no significant differences in the risk of definite or probable stent thrombosis were recorded according to treatment arm in both study groups (4.0% versus 3.1%; HR, 1.30; 95% CI, 0.49-3.41; P=0.60 for diabetic patients and 2.4% versus 3.4%; HR, 0.70; 95% CI, 0.39-1.25; P=0.23, in nondiabetics). CONCLUSIONS In the prespecified subgroup analysis of the BIOSCIENCE trial, clinical outcomes among diabetic patients treated with BP-SES or DP-EES were comparable at 1 year. CLINICAL TRIAL REGISTRATION URL: http://www.clinicaltrials.gov. Unique identifier: NCT01443104.

Formato

application/pdf

Identificador

http://boris.unibe.ch/69475/1/Franzone%20CircCardiovascInterv%202015.pdf

Franzone, Anna; Pilgrim, Thomas; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Räber, Lorenz; Stortecky, Stefan; Wenaweser, Peter Martin; Jüni, Peter; Windecker, Stephan (2015). Clinical Outcomes According to Diabetic Status in Patients Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents: Prespecified Subgroup Analysis of the BIOSCIENCE Trial. Circulation: Cardiovascular interventions, 8(6), e002319. Lippincott Williams & Wilkins 10.1161/CIRCINTERVENTIONS.114.002319 <http://dx.doi.org/10.1161/CIRCINTERVENTIONS.114.002319>

doi:10.7892/boris.69475

info:doi:10.1161/CIRCINTERVENTIONS.114.002319

info:pmid:26043895

urn:issn:1941-7632

Idioma(s)

eng

Publicador

Lippincott Williams & Wilkins

Relação

http://boris.unibe.ch/69475/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Franzone, Anna; Pilgrim, Thomas; Heg, Dik; Roffi, Marco; Tüller, David; Vuilliomenet, André; Muller, Olivier; Cook, Stéphane; Weilenmann, Daniel; Kaiser, Christoph; Jamshidi, Peiman; Räber, Lorenz; Stortecky, Stefan; Wenaweser, Peter Martin; Jüni, Peter; Windecker, Stephan (2015). Clinical Outcomes According to Diabetic Status in Patients Treated With Biodegradable Polymer Sirolimus-Eluting Stents Versus Durable Polymer Everolimus-Eluting Stents: Prespecified Subgroup Analysis of the BIOSCIENCE Trial. Circulation: Cardiovascular interventions, 8(6), e002319. Lippincott Williams & Wilkins 10.1161/CIRCINTERVENTIONS.114.002319 <http://dx.doi.org/10.1161/CIRCINTERVENTIONS.114.002319>

Palavras-Chave #610 Medicine & health #360 Social problems & social services
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed