Notification of abnormal lab test results in an electronic medical record: do any safety concerns remain?


Autoria(s): Singh, Hardeep; Thomas, Eric J; Sittig, Dean F; Wilson, Lindsey; Espadas, Donna; Khan, Myrna M; Petersen, Laura A
Data(s)

01/03/2010

Resumo

BACKGROUND: Follow-up of abnormal outpatient laboratory test results is a major patient safety concern. Electronic medical records can potentially address this concern through automated notification. We examined whether automated notifications of abnormal laboratory results (alerts) in an integrated electronic medical record resulted in timely follow-up actions. METHODS: We studied 4 alerts: hemoglobin A1c > or =15%, positive hepatitis C antibody, prostate-specific antigen > or =15 ng/mL, and thyroid-stimulating hormone > or =15 mIU/L. An alert tracking system determined whether the alert was acknowledged (ie, provider clicked on and opened the message) within 2 weeks of transmission; acknowledged alerts were considered read. Within 30 days of result transmission, record review and provider contact determined follow-up actions (eg, patient contact, treatment). Multivariable logistic regression models analyzed predictors for lack of timely follow-up. RESULTS: Between May and December 2008, 78,158 tests (hemoglobin A1c, hepatitis C antibody, thyroid-stimulating hormone, and prostate-specific antigen) were performed, of which 1163 (1.48%) were transmitted as alerts; 10.2% of these (119/1163) were unacknowledged. Timely follow-up was lacking in 79 (6.8%), and was statistically not different for acknowledged and unacknowledged alerts (6.4% vs 10.1%; P =.13). Of 1163 alerts, 202 (17.4%) arose from unnecessarily ordered (redundant) tests. Alerts for a new versus known diagnosis were more likely to lack timely follow-up (odds ratio 7.35; 95% confidence interval, 4.16-12.97), whereas alerts related to redundant tests were less likely to lack timely follow-up (odds ratio 0.24; 95% confidence interval, 0.07-0.84). CONCLUSIONS: Safety concerns related to timely patient follow-up remain despite automated notification of non-life-threatening abnormal laboratory results in the outpatient setting.

Identificador

http://digitalcommons.library.tmc.edu/uthmed_docs/222

http://www.ncbi.nlm.nih.gov/pmc/articles/PMC2878665/?tool=pmcentrez

Publicador

DigitalCommons@The Texas Medical Center

Fonte

UT Medical School Journal Articles

Palavras-Chave #Communication #Diagnostic Errors #Female #Follow-Up Studies #Hepatitis C #Humans #Male #Medical Records Systems #Computerized #Physician's Practice Patterns #Primary Health Care #Retrospective Studies #United States #Medical Records Systems, Computerized #Medicine and Health Sciences
Tipo

text