Electrocardiographic ST-segment monitoring during controlled occlusion of coronary arteries


Autoria(s): Haeberlin, Andreas; Studer, Evelyn; Niederhauser, Thomas; Stoller, Michael; Marisa, Thanks; Götte, Josef; Jacomet, Marcel; Traupe, Tobias; Seiler, Christian; Vogel, Rolf
Data(s)

01/02/2014

Resumo

Background: Ischemia monitoring cannot always be performed by 12-lead ECG. Hence, the individual performance of the ECG leads is crucial. No experimental data on the ECG's specificity for transient ischemia exist. Methods: In 45 patients a 19-lead ECG was registered during a 1-minute balloon occlusion of a coronary artery (left anterior descending artery [LAD], right coronary artery [RCA] or left circumflex artery [LCX]). ST-segment shifts and sensitivity/specificity of the leads were measured. Results: During LAD occlusion, V3 showed maximal ST-segment elevation (0.26 mV [IQR 0.16–0.33 mV], p = 0.001) and sensitivity/specificity (88% and 80%). During RCA occlusion, III showed maximal ST-elevation (0.2 mV [IQR 0.09–0.26 mV], p = 0.004), aVF had the best sensitivity/specificity (85% and 68%). During LCX occlusion, V6 showed maximal ST-segment elevation (0.04 mV [IQR 0.02–0.14 mV], p = 0.005), and sensitivity/specificity was (31%/92%) but could be improved (63%/72%) using an optimized cut-off for ischemia. Conclusion: V3, aVF and V6 show the best performance to detect transient ischemia.

Formato

application/pdf

Identificador

http://boris.unibe.ch/48135/1/1-s2.0-S0022073613005554-main.pdf

Haeberlin, Andreas; Studer, Evelyn; Niederhauser, Thomas; Stoller, Michael; Marisa, Thanks; Götte, Josef; Jacomet, Marcel; Traupe, Tobias; Seiler, Christian; Vogel, Rolf (2014). Electrocardiographic ST-segment monitoring during controlled occlusion of coronary arteries. Journal of Electrocardiology, 47(1), pp. 29-37. Churchill Livingstone 10.1016/j.jelectrocard.2013.10.003 <http://dx.doi.org/10.1016/j.jelectrocard.2013.10.003>

doi:10.7892/boris.48135

info:doi:10.1016/j.jelectrocard.2013.10.003

urn:issn:1532-8430

Idioma(s)

eng

Publicador

Churchill Livingstone

Relação

http://boris.unibe.ch/48135/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Haeberlin, Andreas; Studer, Evelyn; Niederhauser, Thomas; Stoller, Michael; Marisa, Thanks; Götte, Josef; Jacomet, Marcel; Traupe, Tobias; Seiler, Christian; Vogel, Rolf (2014). Electrocardiographic ST-segment monitoring during controlled occlusion of coronary arteries. Journal of Electrocardiology, 47(1), pp. 29-37. Churchill Livingstone 10.1016/j.jelectrocard.2013.10.003 <http://dx.doi.org/10.1016/j.jelectrocard.2013.10.003>

Palavras-Chave #610 Medicine & health #570 Life sciences; biology
Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed