Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: comparative sequential assessment with optical coherence tomography until complete resorption of the polymer


Autoria(s): Gutiérrez-Chico, Juan Luis; Jüni, Peter; García-García, Héctor M; Regar, Evelyn; Nüesch, Eveline; Borgia, Francesco; van der Giessen, Willem J; Davies, Simon; van Geuns, Robert Jan; Secco, Gioel Gabrio; Meis, Susanne; Windecker, Stephan; Serruys, Patrick W; di Mario, Carlo
Data(s)

2011

Resumo

Biolimus-eluting stents (BESs) with a biodegradable polymer in abluminal coating achieve more complete coverage at 9 months compared with sirolimus-eluting stents (SESs) with a durable polymer, as assessed by optical coherence tomography (OCT). Whether this advantage persists or augments after complete resorption of the polymer (>12 months) is unknown.

Formato

application/pdf

Identificador

http://boris.unibe.ch/7209/1/Guti%C3%A9rrez-Chico%20AmHeartJ%202011.pdf

Gutiérrez-Chico, Juan Luis; Jüni, Peter; García-García, Héctor M; Regar, Evelyn; Nüesch, Eveline; Borgia, Francesco; van der Giessen, Willem J; Davies, Simon; van Geuns, Robert Jan; Secco, Gioel Gabrio; Meis, Susanne; Windecker, Stephan; Serruys, Patrick W; di Mario, Carlo (2011). Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: comparative sequential assessment with optical coherence tomography until complete resorption of the polymer. American Heart Journal, 162(5), pp. 922-931. St. Louis, Mo.: Elsevier 10.1016/j.ahj.2011.09.005 <http://dx.doi.org/10.1016/j.ahj.2011.09.005>

doi:10.7892/boris.7209

info:doi:10.1016/j.ahj.2011.09.005

info:pmid:22093210

urn:issn:0002-8703

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/7209/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Gutiérrez-Chico, Juan Luis; Jüni, Peter; García-García, Héctor M; Regar, Evelyn; Nüesch, Eveline; Borgia, Francesco; van der Giessen, Willem J; Davies, Simon; van Geuns, Robert Jan; Secco, Gioel Gabrio; Meis, Susanne; Windecker, Stephan; Serruys, Patrick W; di Mario, Carlo (2011). Long-term tissue coverage of a biodegradable polylactide polymer-coated biolimus-eluting stent: comparative sequential assessment with optical coherence tomography until complete resorption of the polymer. American Heart Journal, 162(5), pp. 922-931. St. Louis, Mo.: Elsevier 10.1016/j.ahj.2011.09.005 <http://dx.doi.org/10.1016/j.ahj.2011.09.005>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

NonPeerReviewed