Value of the SYNTAX score for risk assessment in the all-comers population of the randomized multicenter LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial


Autoria(s): Wykrzykowska, Joanna J; Garg, Scot; Girasis, Chrysafios; de Vries, Ton; Morel, Marie-Angele; van Es, Gerrit-Anne; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Corti, Roberto; Eberli, Franz; Wijns, William; Morice, Marie-Claude; di Mario, Carlo; van Geuns, Robert Jan; Juni, Peter; Windecker, Stephan; Serruys, Patrick W
Data(s)

2010

Resumo

OBJECTIVES: We aimed to assess the predictive value of the SYNTAX score (SXscore) for major adverse cardiac events in the all-comers population of the LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. BACKGROUND: The SXscore has been shown to be an effective predictor of clinical outcomes in patients with multivessel disease undergoing percutaneous coronary intervention. METHODS: The SXscore was prospectively collected in 1,397 of the 1,707 patients enrolled in the LEADERS trial (patients after surgical revascularization were excluded). Post hoc analysis was performed by stratifying clinical outcomes at 1-year follow-up, according to 1 of 3 SXscore tertiles. RESULTS: The 1,397 patients were divided into tertiles based on the SXscore in the following fashion: SXscore<or=8 (SXlow) (n=464), SXscore>8 and <or=16 (SXmid) (n=472), and SXscore>16 (SXhigh) (n=461). At 1-year follow-up, there was a significantly lower number of patients with major cardiac event-free survival in the highest tertile of SXscore (SXlow=92.2%, SXmid=91.1%, and SXhigh=84.6%; p<0.001). Death occurred in 1.5% of SXlow patients, 2.1% of SXmid patients, and 5.6% of SXhigh patients (hazard ratio [HR]: 1.97, 95% confidence interval [CI]: 1.29 to 3.01; p=0.002). The myocardial infarction rate tended to be higher in the SXhigh group. Target vessel revascularization was 11.3% in the SXhigh group compared with 6.3% and 7.8% in the SXlow and SXmid groups, respectively (HR: 1.38, 95% CI: 1.1 to 1.75; p=0.006). Composite of cardiac death, myocardial infarction, and clinically indicated target vessel revascularization was 7.8%, 8.9%, and 15.4% in the SXlow, SXmid, and SXhigh groups, respectively (HR: 1.47, 95% CI: 1.19 to 1.81; p<0.001). CONCLUSIONS: The SXscore, when applied to an all-comers patient population treated with drug-eluting stents, may allow prospective risk stratification of patients undergoing percutaneous coronary intervention. (LEADERS Trial Limus Eluted From A Durable Versus ERodable Stent Coating; NCT00389220).

Formato

application/pdf

Identificador

http://boris.unibe.ch/1631/1/Wykrzykowska%20JAmCollCardiol%202010.pdf

Wykrzykowska, Joanna J; Garg, Scot; Girasis, Chrysafios; de Vries, Ton; Morel, Marie-Angele; van Es, Gerrit-Anne; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Corti, Roberto; Eberli, Franz; Wijns, William; Morice, Marie-Claude; di Mario, Carlo; van Geuns, Robert Jan; Juni, Peter; Windecker, Stephan; Serruys, Patrick W (2010). Value of the SYNTAX score for risk assessment in the all-comers population of the randomized multicenter LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. Journal of the American College of Cardiology, 56(4), 272-277.. New York, N.Y.: Elsevier 10.1016/j.jacc.2010.03.044 <http://dx.doi.org/10.1016/j.jacc.2010.03.044>

doi:10.7892/boris.1631

info:doi:10.1016/j.jacc.2010.03.044

info:pmid:20633818

urn:issn:0735-1097

Idioma(s)

eng

Publicador

Elsevier

Relação

http://boris.unibe.ch/1631/

Direitos

info:eu-repo/semantics/restrictedAccess

Fonte

Wykrzykowska, Joanna J; Garg, Scot; Girasis, Chrysafios; de Vries, Ton; Morel, Marie-Angele; van Es, Gerrit-Anne; Buszman, Pawel; Linke, Axel; Ischinger, Thomas; Klauss, Volker; Corti, Roberto; Eberli, Franz; Wijns, William; Morice, Marie-Claude; di Mario, Carlo; van Geuns, Robert Jan; Juni, Peter; Windecker, Stephan; Serruys, Patrick W (2010). Value of the SYNTAX score for risk assessment in the all-comers population of the randomized multicenter LEADERS (Limus Eluted from A Durable versus ERodable Stent coating) trial. Journal of the American College of Cardiology, 56(4), 272-277.. New York, N.Y.: Elsevier 10.1016/j.jacc.2010.03.044 <http://dx.doi.org/10.1016/j.jacc.2010.03.044>

Tipo

info:eu-repo/semantics/article

info:eu-repo/semantics/publishedVersion

PeerReviewed