RNA extraction from ten year old formalin-fixed paraffin-embedded breast cancer samples: a comparison of column purification and magnetic bead-based technologies


Autoria(s): Silva, Alfredo Ribeiro da; Zhang, Haiyu ; Jeffrey, Stefanie S
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

26/08/2013

26/08/2013

2007

Resumo

Abstract Background The development of protocols for RNA extraction from paraffin-embedded samples facilitates gene expression studies on archival samples with known clinical outcome. Older samples are particularly valuable because they are associated with longer clinical follow up. RNA extracted from formalin-fixed paraffin-embedded (FFPE) tissue is problematic due to chemical modifications and continued degradation over time. We compared quantity and quality of RNA extracted by four different protocols from 14 ten year old and 14 recently archived (three to ten months old) FFPE breast cancer tissues. Using three spin column purification-based protocols and one magnetic bead-based protocol, total RNA was extracted in triplicate, generating 336 RNA extraction experiments. RNA fragment size was assayed by reverse transcription-polymerase chain reaction (RT-PCR) for the housekeeping gene glucose-6-phosphate dehydrogenase (G6PD), testing primer sets designed to target RNA fragment sizes of 67 bp, 151 bp, and 242 bp. Results Biologically useful RNA (minimum RNA integrity number, RIN, 1.4) was extracted in at least one of three attempts of each protocol in 86–100% of older and 100% of recently archived ("months old") samples. Short RNA fragments up to 151 bp were assayable by RT-PCR for G6PD in all ten year old and months old tissues tested, but none of the ten year old and only 43% of months old samples showed amplification if the targeted fragment was 242 bp. Conclusion All protocols extracted RNA from ten year old FFPE samples with a minimum RIN of 1.4. Gene expression of G6PD could be measured in all samples, old and recent, using RT-PCR primers designed for RNA fragments up to 151 bp. RNA quality from ten year old FFPE samples was similar to that extracted from months old samples, but quantity and success rate were generally higher for the months old group. We preferred the magnetic bead-based protocol because of its speed and higher quantity of extracted RNA, although it produced similar quality RNA to other protocols. If a chosen protocol fails to extract biologically useful RNA from a given sample in a first attempt, another attempt and then another protocol should be tried before excluding the case from molecular analysis.

The RT-PCR primers for G6PD were designed by Liu et al., reference 26. This research was supported by funds from the California Breast Cancer Research Program of the University of California, Grant Number 11IB-0175 (SSJ) and by a grant from Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES – BEX0762067 (ARS).

The RTPCR primers for G6PD were designed by Liu et al., reference 26. This research was supported by funds from the California Breast Cancer Research Program of the University of California, Grant Number 11IB0175 (SSJ) and by a grant from Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES – BEX0762067 (ARS).

Identificador

1471-2199

http://www.producao.usp.br/handle/BDPI/32817

10.1186/1471-2199-8-118

http://www.biomedcentral.com/1471-2199/8/118

Idioma(s)

eng

Relação

BMC Molecular Biology

Direitos

openAccess

Ribeiro-Silva et al; licensee BioMed Central Ltd. - This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Tipo

article

original article