Capillary electrophoretic enantioselective determination of zopiclone and its impurities


Autoria(s): Tonon, Milena Araujo; Bonato, Pierina Sueli
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

25/09/2013

25/09/2013

2012

Resumo

A capillary electrophoretic enantioselective method with UV detection was developed and validated for the simultaneous quantification of zopiclone enantiomers and its impurities, zopiclone-N-oxide enantiomers, and 2-amino-5-chloropyridine, in tablets. The analytes were extracted from the tablets using ACN and were separated in an uncoated fused-silica capillary (50 mu m, 42 cm effective length, 50 cm total length) using 80 mM sodium phosphate buffer pH 2.5 and 5 mM carboxymethyl-beta-cyclodextrin as running buffer. The analytes and the internal standard (trimethoprim) were detected at 305 and 200 nm, respectively. A voltage of 27 kV was applied and the capillary temperature was maintained at 25 degrees C. All enantiomers were analyzed within 8 min and linear calibration curves over the concentration range of 0.40.8 mg mL-1 for each zopiclone enantiomer, 0.81.6 mu g mL-1 for 2-amino-5-chloropyridine and 0.40.8 mu g mL-1 for each zopiclone-N-oxide enantiomer were obtained. The coefficients of correlation obtained for the linear curves were greater than 0.99. The intra-day and inter-day accuracy and precision were lower than 2% for all analytes. This validated method was employed to study the degradation and racemization of zopiclone under stress conditions. This application demonstrated the importance of a stability-indicating assay method for this drug.

Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)

Conselho Nacional de Desenvolvimento Cientifico e Tecnologico (CNPq)

Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)

Fundacao de Amparo a Pesquisa do Estado de Sao Paulo (FAPESP)

Identificador

ELECTROPHORESIS, HOBOKEN, v. 33, n. 11, supl. 4, Part 1-2, pp. 1606-1612, JUN, 2012

0173-0835

http://www.producao.usp.br/handle/BDPI/33688

10.1002/elps.201100583

http://dx.doi.org/10.1002/elps.201100583

Idioma(s)

eng

Publicador

WILEY-BLACKWELL

HOBOKEN

Relação

ELECTROPHORESIS

Direitos

closedAccess

Copyright WILEY-BLACKWELL

Palavras-Chave #CAPILLARY ELECTROPHORESIS #ENANTIOSELECTIVE ANALYSIS #IMPURITIES #STABILITY #ZOPICLONE #CHIRAL RESOLUTION #HUMAN PLASMA #METABOLITES #ENANTIOMERS #URINE #HPLC #BIOCHEMICAL RESEARCH METHODS #CHEMISTRY, ANALYTICAL
Tipo

article

original article

publishedVersion