Evaluation of the physicochemical properties and push-out bond strength of mta-based root canal cement


Autoria(s): Chávez-Andrade, Gisele Moraima; Kuga, Milton Carlos; Duarte, Marco Antonio Hungaro; Leonardo, Renato de Toledo; Keine, Katia Cristina; Sant 'anna-Junior, Arnaldo; Só, Marcus Vinicius Reis
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

06/08/2015

06/08/2015

2013

Resumo

Aim: This study investigated the flowability, setting time, pH, calcium release and bond strength of a MTA-based cement (MTA Fillapex®) compared to AH Plus and Sealapex. Materials and methods: For the flowability test, the ISO 6876:2001 specification was utilized and for the setting time test, the ASTM C266-03 specification was utilized. For the pH and calcium release measurements, 10 samples were prepared for each group and analyzed for several different periods. For the push-out test, dentin disks were distributed into three groups, according to the cement utilized and into three subgroups, according to the root third (n = 10). After obturation, the specimens underwent push-out testing. The data were compared statistically using a significance level of 5%. Results: The flowability of all materials was found to be similar (p > 0.05). The setting times were different among the groups tested (MTA Fillapex < Sealapex < AH Plus) (p < 0.05). At days 7 and 28, the MTA Fillapex presented the higher pH values (p < 0.05). At 24 hours and at 14 days, the calcium release of the MTA Fillapex was similar to that of Sealapex (p > 0.05). AH Plus presented the lowest pH and calcium release values (p < 0.05). In all root thirds, the adhesion to the dentin of the MTA Fillapex and Sealapex were significantly lower than that of AH Plus (p < 0.05). Conclusion: MTA Fillapex and Sealapex presented several similar properties and both were found to be different than AH Plus. Clinical significance: This study evaluated the physicochemical and mechanical properties of new MTA-based root canal cement, in order to use this scaler in root canal fillings. MTA Fillapex showed satisfactory properties for clinical use.

Formato

1094-1099

Identificador

http://www.jaypeejournals.com/eJournals/Abstract.aspx?id=5833&AID=24&num=18

The Journal of contemporary Dental Practice, v. 14, n. 6, p. 1094-1099, 2013.

0974-0333

http://hdl.handle.net/11449/125887

http://dx.doi.org/10.5005/jp-journals-10024-1457

9314888467416908

Idioma(s)

eng

Relação

The Journal of contemporary Dental Practice

Direitos

openAccess

Palavras-Chave #Adhesion #Calcium #MTA #pH #Push-out
Tipo