On-line extraction and determination of carbofuran in raw milk by direct HPLC injection on an ISRP column


Autoria(s): Menezes, Manoel Lima de; Felix, G.; Demarchi, ACCO
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/01/1998

Resumo

A method has been developed for extraction and determination of carbofuran in milk. The method involved direct injection of raw milk on to a human serum albumin dimethyloctyl-silica gel (HSA-Cs) column and the use of 80:20 (v/v) 0.01 M phosphate buffer pH 5.5 - acetonitrile as mobile phase. UV spectrophotometric detection was performed at 220 nm. Identification was based on retention time. Quantification was performed by automatic peak-area determination and was calibrated by use of an external standard.

Formato

81-83

Identificador

http://dx.doi.org/10.1007/BF02466790

Chromatographia. Wiesbaden: Vieweg, v. 47, n. 1-2, p. 81-83, 1998.

0009-5893

http://hdl.handle.net/11449/31962

10.1007/BF02466790

WOS:000071631000013

Idioma(s)

eng

Publicador

Vieweg

Relação

Chromatographia

Direitos

closedAccess

Palavras-Chave #column liquid chromatography #carbofuran pesticides #on-line analysis of milk
Tipo

info:eu-repo/semantics/article