Sistema de injeção em fluxo espectrofotométrico para monitorar peróxido de hidrogênio em processo de fotodegradação por reação foto-Fenton


Autoria(s): Oliveira, Mirela C.; Nogueira, Raquel Fernandes Pupo; Gomes Neto, José Anchieta; Jardim, Wilson F.; Rohwedder, Jarbas J. R.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/04/2001

Resumo

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

A flow injection spectrophotometric system was projected for monitoring hydrogen peroxide during photodegradation of organic contaminants in photo-Fenton processes (Fe2+/H2O2/UV). Sample is injected manually in a carrier stream and then receives by confluence a 0.1 mol L-1 NH4VO3 solution in 0.5 mol L-1 H2SO4 medium. The product formed shows absorption at 446 nm which is recorded as a peak with height proportional to H2O2 concentration. The performance of the proposed system was evaluated by monitoring the consumption of H2O2 during the photodegradation of dichloroacetic acid solution by foto-Fenton reaction.

Formato

188-190

Identificador

http://dx.doi.org/10.1590/S0100-40422001000200007

Química Nova. Sociedade Brasileira de Química, v. 24, n. 2, p. 188-190, 2001.

0100-4042

http://hdl.handle.net/11449/25902

10.1590/S0100-40422001000200007

S0100-40422001000200007

S0100-40422001000200007.pdf

Idioma(s)

por

Publicador

Sociedade Brasileira de Química

Relação

Química Nova

Direitos

openAccess

Palavras-Chave #hydrogen peroxide #flow injection analysis #foto-Fenton
Tipo

info:eu-repo/semantics/article