Determination of metal ions in natural waters by flame-AAS after preconcentration on a 5-amino-1,3,4-thiadiazole-2-thiol modified silica gel.


Autoria(s): Padilha, P. D.; Gomes, LAD; Padilha, CCF; Moreira, J. C.; Dias, N. L.
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

01/01/1999

Resumo

5-amino-1,3,4-thiadiazole-2-thiol groups attached on a silica gel surface have been used for adsorption of Cd(II), Co(II), Cu(II), Fe(III), Ni(II), Pb(II) and Zn(II) from aqueous solutions. The adsorption capacities for each metal ion were (in mmol.g(-1)): Cd(II)= 0.35, Co(II)= 0.10, Cu(II)= 0.15, Fe(III)= 0.20, Hg(Il)= 0.46, Ni(II)= 0.16, Pb(II)= 0.13 and Zn(II)= 0.15. The modified silica gel was applied in the preconcentration and quantification of trace level metal ions present in water samples (river, and bog water).

Formato

1807-1820

Identificador

http://dx.doi.org/10.1080/00032719908542935

Analytical Letters. New York: Marcel Dekker Inc., v. 32, n. 9, p. 1807-1820, 1999.

0003-2719

http://hdl.handle.net/11449/19026

10.1080/00032719908542935

WOS:000081342800009

Idioma(s)

eng

Publicador

Marcel Dekker Inc

Relação

Analytical Letters

Direitos

closedAccess

Palavras-Chave #preconcentration #5-amino-1,3,4-thiadiazole-2-thiol modified silica gel #water analysis
Tipo