Effects of pigment, disinfection, and accelerated aging on the hardness and deterioration of a facial silicone elastomer


Autoria(s): Goiato, Marcelo Coelho; Pesqueira, Aldieris Alves; Moreno, Amalia; Santos, Daniela Micheline dos; Haddad, Marcela Filie; Bannwart, Lisiane Cristina
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

30/09/2013

20/05/2014

30/09/2013

20/05/2014

01/09/2012

Resumo

The failure of facial prostheses is caused by limitations in their flexibility and durability. Therefore, we evaluated the effects of disinfection and aging on Shore A hardness and deterioration of a facial silicone with different pigmentations. Twenty samples with addition of each pigment (ceramic (C), make-up (M)) and without pigment (L) were made. For each pigment type and no pigment, 10 samples were subjected to two types of disinfectant solution (soap (S) and Efferdent (E)), totaling sixty samples. The specimens were disinfected three times per week for 60 days, and subjected to accelerated aging for 1008 h. The hardness of the facial silicone was measured with a durometer, and its deterioration was evaluated by obtaining the weight difference over time. Both the hardness and weight of the samples were measured at baseline, after chemical disinfection, and periodically during accelerated aging (252, 504, and 1008 h). Deterioration was calculated during the periods between baseline and chemical disinfection, and between baseline and each aging period. The results were analyzed using three-way repeated measures ANOVA and the Tukey's HSD Post-hoc test (alpha = 0.05). Specifically, samples containing pigment exhibited significantly higher hardness and deterioration values than those lacking pigment (P < 0.05). In addition, period of time (disinfection and accelerated aging) statistically increased the hardness and deterioration values of the silicone (P < 0.05). It can be concluded that both pigment and time statistically affected the hardness and deterioration of the silicone elastomer. (c) 2012 Elsevier Ltd. All rights reserved.

Formato

1577-1580

Identificador

http://dx.doi.org/10.1016/j.polymdegradstab.2012.06.033

Polymer Degradation and Stability. Oxford: Elsevier B.V., v. 97, n. 9, p. 1577-1580, 2012.

0141-3910

http://hdl.handle.net/11449/15286

10.1016/j.polymdegradstab.2012.06.033

WOS:000308051500003

Idioma(s)

eng

Publicador

Elsevier B.V.

Relação

Polymer Degradation and Stability

Direitos

closedAccess

Palavras-Chave #Deterioration #Polymer #Disinfection #Hardness #Accelerated aging
Tipo

info:eu-repo/semantics/article