Analysis of the effects of irradiation in osseointegrated dental implants


Autoria(s): Guedes de Oliveira, Joao Augusto; do Amaral Escada, Ana Lucia; Rosifini, Maria Cristina; Rezende, Alves; Mathor, Monica Beatriz; Rosifini Alves Claro, Ana Paula
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

30/09/2013

20/05/2014

30/09/2013

20/05/2014

01/04/2012

Resumo

Objective: The purpose of the present study was to evaluate the influence of radiation in osseointegrated dental implants installed in tibiae of rats.Material and methods: Screw-shaped implants (2.5 mm diameter by 3.5 mm length) were custom made from commercially pure titanium bars. Titanium implants were blasted and sterilized before implantation. Animals were divided into two groups of 12 animals each and the rats were not paired after the groups' formation. The experimental group (group 1) received external irradiation 4 weeks after surgery while in the control group (group 2) animals were kept free of radiation. The shear strength required to detach the implant from bone was measured by push-out testing and osseointegration was histologically evaluated.Results: Results showed that the compressive strength of irradiated implants (33.49 MPa) was significantly lower than the compressive strength of non-irradiated implants (48.05 MPa).Conclusions: We concluded that the mechanical strength bonding between implants and host tissues decreased after irradiation.

Formato

511-514

Identificador

http://dx.doi.org/10.1111/j.1600-0501.2010.02149.x

Clinical Oral Implants Research. Malden: Wiley-blackwell, v. 23, n. 4, p. 511-514, 2012.

0905-7161

http://hdl.handle.net/11449/15239

10.1111/j.1600-0501.2010.02149.x

WOS:000301175100018

Idioma(s)

eng

Publicador

Wiley-Blackwell

Relação

Clinical Oral Implants Research

Direitos

closedAccess

Palavras-Chave #biomechanical properties #osseointegration #radiotherapy
Tipo

info:eu-repo/semantics/article