Determination of ciclopirox olamine in pharmaceutical products by capillary electrophoresis with capacitively coupled contactless conductivity detection


Autoria(s): FELIX, Fabiana Silva; LAGO, Claudimir Lucio do; ANGNES, Lucio
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

20/10/2012

20/10/2012

2011

Resumo

This paper describes the determination of ciclopirox olamine in pharmaceutical formulations using capillary electrophoresis with capacitively coupled contactless conductivity detection. In an alkaline medium, ciclopirox olamine is converted into an anionic species and its detection is possible in capillary electrophoresis with capacitively coupled contactless conductivity detection without an electroosmotic flow modifier, because it is a low-mobility species. A linear working range from 2.64 to 264 mu g/mL in sodium hydroxide electrolyte as well as low detection limit (0.39 mu g/mL) and a good repeatability (RSD = 3.4% for 264 mu g/mL ciclopirox solution (n = 10)) were achieved. It was also possible to determine olamine in its cationic form when acetic acid was used as the electrolyte solution. The results obtained include a linear range from 26.4 to 184.8 mu g/mL and a detection limit of 2.6 mu g/mL olamine. The proposed methods were applied to the analysis of commercial pharmaceutical products and the results were compared with the values indicated by the manufacturer as well as those obtained using a titrimetric method recommended by American Pharmacopoeia.

FAPESP

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

CNPq

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

CAPES

IM2C (Instituto do Milenio de Materiais Complexos)

IM2C (Instituto do Milenio de Materiais Complexos)

RENAMI project

RENAMI project

SAMUTI project

SAMUTI project

Identificador

ELECTROPHORESIS, v.32, n.8, p.900-905, 2011

0173-0835

http://producao.usp.br/handle/BDPI/31379

10.1002/elps.201000612

http://dx.doi.org/10.1002/elps.201000612

Idioma(s)

eng

Publicador

WILEY-BLACKWELL

Relação

Electrophoresis

Direitos

restrictedAccess

Copyright WILEY-BLACKWELL

Palavras-Chave #Antimycotic drugs #Capillary zone electrophoresis #Ciclopirox olamine #Contactless conductivity detection #Pharmaceutical products #ZONE-ELECTROPHORESIS #PRECOLUMN DERIVATIZATION #SEPARATION #MEMBRANE #NAIL #Biochemical Research Methods #Chemistry, Analytical
Tipo

article

original article

publishedVersion