Demographic characteristics and prevalence of serologic markers among blood donors who use confidential unit exclusion (CUE) in Sao Paulo, Brazil: implications for modification of CUE polices in Brazil


Autoria(s): ALMEIDA-NETO, Cesar de; LIU, Jing; WRIGHT, David J.; MENDRONE-JUNIOR, Alfredo; TAKECIAN, Pedro L.; SUN, Yu; FERREIRA, Joao Eduardo; CHAMONE, Dalton de Alencar Fischer; BUSCH, Michael P.; SABINO, Ester Cerdeira; NHLBI Retrovirus Epidemiol Donor
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

20/10/2012

20/10/2012

2011

Resumo

BACKGROUND: This study evaluated demographic profiles and prevalence of serologic markers among donors who used confidential unit exclusion (CUE) to assess the effectiveness of CUE and guide public policies regarding the use of CUE for enhancing safety versus jeopardizing the blood supply by dropping CUE. STUDY DESIGN AND METHODS: We conducted a cross-sectional analysis of whole blood donations at a large public blood center in Sao Paulo from July 2007 through June 2009, compared demographic data, and confirmed serologic results among donors who used and who have never used CUE (CUE never). RESULTS: There were 265,550 whole blood units collected from 181,418 donors from July 2007 through June 2009. A total of 9658 (3.6%) units were discarded, 2973 (1.1%) because CUE was used at the current donation (CUE now) and 6685 (2.5%) because CUE was used in the past (CUE past). The CUE rate was highest among donors with less than 8 years of education (odds ratio [OR], 2.78; 95% confidence interval [CI], 2.51-3.08). CUE now donations were associated with higher positive infectious disease marker rates than CUE never donations (OR, 1.41; CI, 1.13-1.77), whereas CUE past donations were not (OR, 1.04; CI, 0.75-1.45). CONCLUSION: The CUE process results in a high rate of unit discard. CUE use on an individual donation appears predictive of a high-risk marker-positive donation and, thus, appears to contribute modestly to blood safety. The policy of discarding units from donors who have previously CUE-positive donations does not improve safety and should be discontinued.

Identificador

TRANSFUSION, v.51, n.1, p.191-197, 2011

0041-1132

http://producao.usp.br/handle/BDPI/30358

10.1111/j.1537-2995.2010.02799.x

http://dx.doi.org/10.1111/j.1537-2995.2010.02799.x

Idioma(s)

eng

Publicador

WILEY-BLACKWELL PUBLISHING, INC

Relação

Transfusion

Direitos

restrictedAccess

Copyright WILEY-BLACKWELL PUBLISHING, INC

Palavras-Chave #HUMAN-IMMUNODEFICIENCY-VIRUS #INFECTIONS #OPTION #RISK #HCV #Hematology
Tipo

article

original article

publishedVersion