Controlled study of 50-Hz repetitive transcranial magnetic stimulation for the treatment of Parkinson disease.


Autoria(s): Benninger, D.H.; Iseki, K.; Kranick, S.; Luckenbaugh, D.A.; Houdayer, E.; Hallett, M.
Data(s)

2012

Resumo

OBJECTIVE: To investigate the safety and efficacy of 50-Hz repetitive transcranial magnetic stimulation (rTMS) in the treatment of motor symptoms in Parkinson disease (PD). BACKGROUND: Progression of PD is characterized by the emergence of motor deficits that gradually respond less to dopaminergic therapy. rTMS has shown promising results in improving gait, a major cause of disability, and may provide a therapeutic alternative. Prior controlled studies suggest that an increase in stimulation frequency might enhance therapeutic efficacy. METHODS: In this randomized, double blind, sham-controlled study, the authors investigated the safety and efficacy of 50-Hz rTMS of the motor cortices in 8 sessions over 2 weeks. Assessment of safety and clinical efficacy over a 1-month period included timed tests of gait and bradykinesia, Unified Parkinson's Disease Rating Scale (UPDRS), and additional clinical, neurophysiological, and neuropsychological parameters. In addition, the safety of 50-Hz rTMS was tested with electromyography-electroencephalogram (EMG-EEG) monitoring during and after stimulation. RESULTS: The authors investigated 26 patients with mild to moderate PD: 13 received 50-Hz rTMS and 13 sham stimulation. The 50-Hz rTMS did not improve gait, bradykinesia, and global and motor UPDRS, but there appeared a short-lived "on"-state improvement in activities of daily living (UPDRS II). The 50-Hz rTMS lengthened the cortical silent period, but other neurophysiological and neuropsychological measures remained unchanged. EMG/EEG recorded no pathological increase of cortical excitability or epileptic activity. There were no adverse effects. CONCLUSION: It appears that 50-Hz rTMS of the motor cortices is safe, but it fails to improve motor performance and functional status in PD. Prolonged stimulation or other techniques with rTMS might be more efficacious but need to be established in future research.

Identificador

https://serval.unil.ch/notice/serval:BIB_1393604A28BE

info:pmid:22593114

https://serval.unil.ch/resource/serval:BIB_1393604A28BE.P001/REF

doi:10.1177/1545968312445636

isiid:000309358400009

Idioma(s)

eng

Direitos

info:eu-repo/semantics/restrictedAccess

Restricted: indefinite embargo

Copying allowed only for non-profit organizations

https://serval.unil.ch/disclaimer

Fonte

Neurorehabilitation and Neural Repair2691096-1105

Tipo

info:eu-repo/semantics/article

article

Formato

application/pdf