On the assessment of time-shift variations from backscattered ultrasound for large temperature changes in biological phantoms


Autoria(s): Teixeira, C. A.; Ruano, M. Graca; Pereira, W. C. A.
Contribuinte(s)

Garreton, L. G.

Data(s)

13/04/2015

13/04/2015

01/01/2010

Resumo

This work reports the assessment of time-shifts (TS) from backscattered ultrasound (BSU) signals when large temperature variations (up to 15 degrees C) were induced in a gel-based phantom. The results showed that during cooling temperature is linear with TS at a rate of approximately 74 ns/degrees C. However during a complete heating/cooling cycle, the relation is highly non-linear. This can be explained by the fact that during cooling the temperature distribution is more uniform. Another problem to report is that TS is very sensitive to external movements.

Identificador

1875-3892

AUT: MRU00118;

http://hdl.handle.net/10400.1/5863

http://dx.doi.org/10.1016/j.phpro.2010.01.088

Idioma(s)

eng

Publicador

Elsevier

Relação

Physics Procedia

Palavras-Chave #Non-invasive temperature estimation #Temperature models #Time-shift estimation #Ultrasound
Tipo

conferenceObject

Direitos

restrictedAccess