Construção de barreiras para diminuir as falhas nas mensurações glicêmicas realizadas pela enfermagem em pacientes críticos com insulina intravenosa


Autoria(s): Raquel de Mendonça Nepomuceno
Contribuinte(s)

Luciana Guimarães Assad

Sandra Regina Maciqueira Pereira

Roberto Carlos Lyra da Silva

Juliana Faria Campos

Lolita Dopico da Silva

Data(s)

08/06/2015

Resumo

Esta pesquisa tem como objeto os fatores que influenciam a mensuração glicêmica realizada pela enfermagem em pacientes que recebem insulina contínua intravenosa utilizando glicosímetros portáteis à beira leito. Vários fatores podem influenciar a mensuração glicêmica, tais como a amostra sanguínea, a calibração do aparelho, a estocagem das fitas-teste, o hematócrito dos pacientes, o uso de vasoaminas e falhas do operador. A partir da Tese de que: A identificação dos fatores que influenciam a mensuração glicêmica realizada pela enfermagem através de glicosímetros é determinante para a eficiência das barreiras de salvaguarda voltadas para a minimização de falhas na sua execução, a fim de garantir resultados glicêmicos confiáveis e, consequentemente, realizar a titulação da insulina com segurança, teve-se como objetivo geral propor ações de enfermagem que funcionem como barreiras para diminuir as falhas nas mensurações glicêmicas realizadas pela enfermagem em pacientes que recebem infusão contínua de insulina. Espera-se contribuir com ações para garantir a adequação e o controle rigoroso da insulina administrada. Estudo observacional, transversal, prospectivo com abordagem quantitativa na análise dos dados, em uma unidade intensiva cirúrgica cardiológica de um hospital público do Rio de Janeiro. As variáveis do estudo foram submetidas a tratamentos estatísticos não paramétricos e às medidas de associação. Foram investigados 42 pacientes com observação de 417 glicemias. Predominaram pacientes do sexo feminino (57,14%), média de idade de 48 (15,85) anos, sem insuficiência renal e sem tratamento dialítico (90,48%). Observou-se PAM com média de 77(10,29) mmHg, uso de vasoaminas (80,95%), PaO2 ≥ 90mmHg em 85,71% e hematócrito <35% em 71,42%. Encontrou-se uma incidência de hipoglicemia de 35,7%, sendo a população dividida em dois grupos, o primeiro (G1) com pacientes que apresentaram hipoglicemia ≤ 60mg/dl (n=15), e o segundo (G2), com pacientes sem hipoglicemia (n=27). O hematócrito baixo foi a característica clínica que apresentou maior associação com a hipoglicemia. Pacientes com esta condição apresentaram 5,60 vezes mais risco de apresentarem hipoglicemia. O uso de vasoaminas elevou 3,3 vezes o risco de hipoglicemia em pacientes com estas medicações. A realização de cirurgias de emergência, a presença de insuficiência renal com tratamento dialítico, e a elevação da PaO2 acima de 90mmHg também apresentaram associação positiva com a hipoglicemia. Das 417 mensurações observadas, predominou o uso de amostra sanguínea de origem arterial. Observou-se que em todas as etapas da técnica de mensuração houve desvio de execução, com exceção de compressão da polpa digital. Os desvios observados que mostraram associação positiva (RR>1) para pacientes com hipoglicemia foram: a falta de calibração do glicosímetro, a falta de verificação da validade/integridade da fita teste, a falta da higienização das mãos e a falta da coleta de até 1 ml de sangue. Construiu-se uma revisão da técnica de mensuração glicêmica com enfoque nos fatores que podem comprometer o resultado glicêmico levando em conta o risco de hipoglicemia. Tornou-se evidente que a compreensão apropriada dos fatores que influenciam a glicemia e a mensuração glicêmica é indispensável para o enfermeiro na obtenção de resultados glicêmicos confiáveis, e assim, evitar erros na titulação das doses de insulina administrada.

This research has as object the factors that affect the glucose measurement performed by nurses in patients receiving continuous intravenous insulin using portable glucometers at the bedside. Many factors can affect the glucose measurement, such as the blood sample, the instrument calibration, the test strips storage, the patients' hematocrit, the use of vasoactive agents, and failures caused by the operator. Taking into account the thesis that the identification of the factors that affect the glucose measurement performed by nursing using glucometers is crucial for the effectiveness of the safeguard barriers aimed to minimizing failures in its implementation, ensuring reliable glycemic results, and consequently for performing titration of insulin safely, the main objective of this study was to propose nursing actions working as barriers to reduce the failures in glucose measurements performed by nurses in patients receiving continuous infusion of insulin. This study intends to contribute with actions to ensure compliance and the strict control in administering insulin. This is an observational, cross-sectional, and prospective study with quantitative approach to data analysis, in a surgical intensive cardiac unit of a public hospital in Rio de Janeiro City, Brazil. The variables of this study were submitted to nonparametric statistical procedures and to measures of association. The survey consisted of 42 patients with observation of 417 blood glucose levels. There was a prevalence of female patients (57.14%), averaging 48 years old (15.85), without renal failure and without dialysis (90.48%). The mean arterial pressure of 77 (10.29) mmHg, vasoactive agents usage (80.95%), PaO2≥90 mmHg in 85.71%, and hematocrit<35% at 71.42% were observed. It was found hypoglycemia incidence at 35.7%. The population was divided into two groups; the first group (G1) consisted of patients with hypoglycemia≤60 mg/dl (n=15) and (2) the second group (G2) with patients without hypoglycemia (n=27). Low hematocrit was clinical feature that showed greater association with hypoglycemia. Patients under this condition were 5.60 times more susceptible to the risks of hypoglycemia. Patients using vasoactive agents had 3.3 times more the risks of hypoglycemia. Emergency surgery, presence of renal failure with dialysis, and increase in PaO2 above 90 mmHg also had a positive association with hypoglycemia. The use of blood sample of arterial origin was prevailing in the 417 observed measurements. It was observed that in all technique steps of the measurement there was implementing deviation, with the exception of the fingertip compression. The observed deviations which showed positive association (RR>1) for patients with hypoglycemia were: (1) lack of glucometer calibration; (2) verification lack of the validity and integrity of the tape test; (3) lack of hand sanitation; and (4) lack of gathering up 1 mL of blood. A review of the glycemic measurement technique was made focusing on factors that may compromise glycemic result, taking into account the hypoglycemia risk. It became clear that the proper understanding of the factors that affect blood glucose and glucose measurement is essential for nurses in obtaining reliable blood glucose results, and, thus, avoiding mistakes in titration administering insulin doses.

Formato

PDF

Identificador

http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=9127

Idioma(s)

pt

Publicador

Biblioteca Digital de Teses e Dissertações da UERJ

Direitos

Liberar o conteúdo dos arquivos para acesso público

Palavras-Chave #Terapia intensiva #Segurança #Enfermagem #Insulina #Glicemia #ENFERMAGEM #Glycemia #Insulin #Nursing #Security #Intensive care
Tipo

Eletronic Thesis or Dissertation

Tese ou Dissertação Eletrônica