Influência do limite e do calibre apical após a instrumentação mecanizada com instrumentos reciprocantes na extrusão bacteriana apical


Autoria(s): João Marcelo da Silva Teixeira
Contribuinte(s)

Rivail Antonio Sergio Fidel

Carlos Augusto de Melo Barbosa

Georgiana Amaral

Data(s)

11/02/2014

Resumo

O objetivo deste estudo foi avaliar ex vivo a extrusão bacteriana apical após instrumentação com um sistema de instrumento único reciprocante e verificar a influência de diferentes limites e diâmetros apicais nesta. Sessenta e quatro raízes de pré-molares foram utilizadas. Os dentes foram acessados e seus canais radiculares foram contaminados com uma suspensão de Enterococcus faecalis e incubados por 30 dias possibilitando crescimento bacteriano em biofilme. Os dentes contaminados foram divididos em quatro grupos com 15 espécimes cada. O calibre dos instrumentos utilizados e comprimento de trabalho de cada grupo foram respectivamente R25 à 0mm do forame, R25 aquém 1mm, R40 a 0mm e R40 aquém 1mm. Foram feitos grupos controle de crescimento bacteriano positivo e negativo. As bactérias extruídas apicalmente durante a instrumentação foram coletadas em frascos de vidro contendo 0,9% de NaCl. As amostras microbiológicas foram retiradas destes frascos e incubadas em meio BHI ágar, durante 24 horas. O crescimento bacteriano foi contado e os resultados foram expressos em unidades formadoras de colônia (UFC). Os dados foram analisados pelo teste estatístico de Kruskal-Wallis. Não houve diferença estatisticamente significante no número de UFC entre os quatro grupos (p>0,05). A partir da análise dos resultados e dentro das limitações deste estudo foi possível concluir que independente do comprimento de trabalho e da ampliação foraminal haverá similar quantidade de extrusão bacteriana.

The aim of this work was to evaluate ex vivo the apical bacterial extrusion after instrumentation with a single instrument reciprocating system and the influence of differents working lengths and apical diameters on it. Sixty-four premolar roots were used. Endodontic access cavities were prepared and root canals were contaminated with an Enterococcus faecalis suspension and incubated for thirty days to promote bacterial biofilm growth. The contaminated teeth were divided into four groups with 15 specimens each. The files used and lengths from each group were respectively R25 at 0mm from foramen, R25 1mm shorter, R40 at 0mm from foramen and R40 1mm shorter. Positive and negative bacterial growth control groups were done. Bacterial extruded from the apical foramen during instrumentation were collected into vials containing 0.9% NaCl. The microbiological samples were taken from the vials and incubated in BHI agar medium during 24h. Bacterial growth was counted and the results were given by colony-forming units (CFU). These data were analyzed by KruskalWallis H-test. After data analysis, no significant difference was found in the number of CFU among the four groups (p > 0.05). Based on the results evaluation and within the limitation of this study, it was possible to conclude that regardless of the working length and foraminal enlargement will be similar amount of bacterial extrusion.

Formato

PDF

Identificador

http://www.bdtd.uerj.br/tde_busca/arquivo.php?codArquivo=6644

Idioma(s)

pt

Publicador

Biblioteca Digital de Teses e Dissertações da UERJ

Direitos

Liberar o conteúdo dos arquivos para acesso público

Palavras-Chave #Reciprocating #Bacteria #Endodontics #Reciprocante #Instrumentação #Bacteriana #Extrusão #Endodontia #ODONTOLOGIA #Extrusion #Files
Tipo

Eletronic Thesis or Dissertation

Tese ou Dissertação Eletrônica