Interfacial area measurement in a gas - liquid ejector for a sodium chloride - air system


Autoria(s): Raghuram, PT
Data(s)

01/05/2009

Resumo

Interfacial area measurement has been carried out experimentally by measuring the bubble size and holdup for air-sodium chloride solution system. The size of the bubble is predominantly established by the air hold up. High speed photography technique for bubble size measurement and gamma ray attenuation method for holdup measurements are followed. The measured values are compared with the theoretically predicted values. Interracial area as a function of the liquid flow rate and also its distance from the nozzle of the ejector has been reported in this paper. The results obtained for this non-reactive system are also compared with those of air-water system.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/21124/1/IJCT_16%283%29_278-282.pdf

Raghuram, PT (2009) Interfacial area measurement in a gas - liquid ejector for a sodium chloride - air system. In: Indian Journal of Chemicla Technology, 16 (3). pp. 278-282.

Publicador

National Institute of Science Communication and Information Resources

Relação

http://www.niscair.res.in/ScienceCommunication/ResearchJournals/rejour/ijct/ijct2k9/ijct_may09.asp#278

http://eprints.iisc.ernet.in/21124/

Palavras-Chave #Chemical Engineering
Tipo

Journal Article

PeerReviewed