Natural Frequencies And Transient Responses Of 3-Phase Rotating Machine Windings


Autoria(s): Chandrasekharaiah, HS
Data(s)

01/09/1986

Resumo

The analysis of transient electrical stresses in the insulation of high voltage rotating machines is rendered difficult because of the existence of capacitive and inductive couplings between phases. The Published theories ignore many of the couplings between phases to obtain the solution. A new procedure is proposed here to determine the transient voltage distribution on rotating machine windings. All the significicant capacitive and inductive couplings between different sections in a phase and between different sections in different phases have been considered in this analysis. The experimental results show good correlation with those computed.

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/21037/1/getPDF.pdf

Chandrasekharaiah, HS (1986) Natural Frequencies And Transient Responses Of 3-Phase Rotating Machine Windings. In: IEEE Transactions on Energy Conversion, 1 (3). 167 -173.

Publicador

IEEE

Relação

http://ieeexplore.ieee.org/search/wrapper.jsp?arnumber=4765751&sourceID=ISI

http://eprints.iisc.ernet.in/21037/

Palavras-Chave #High Voltage Engineering (merged with EE)
Tipo

Journal Article

PeerReviewed