Breakdown voltage and V-Z characteristics of sodium vapour using coaxial cylindrical electrodes


Autoria(s): Hemamalini, N; Lakshminarasimha, CS; Naidu, MS
Data(s)

1983

Resumo

Experimental results for breakdown voltage of sodium vapour measured for the first time using coaxial cylindrical electrodes of fixed gap distance (5 mm) and pressure (corrected to2 0 "C) in the range2 1 to 652 Pa are reported, and are founfdo l ltoow Paschen's Law. The investigations also reveal that V th-Ie characteristics are pressure dependent; the current during the breakdown and the buoifl dc-uurpre nt after a breakdoiws nei ther positive or negative. in spite of the central cylinder being always maintained at a positive potential

Formato

application/pdf

Identificador

http://eprints.iisc.ernet.in/20592/1/article1.pdf

Hemamalini, N and Lakshminarasimha, CS and Naidu, MS (1983) Breakdown voltage and V-Z characteristics of sodium vapour using coaxial cylindrical electrodes. In: Journal of Physics D: Applied Physics, 16 (8). pp. 1489-1492.

Publicador

Institute of Physics

Relação

http://www.iop.org/EJ/article/0022-3727/16/8/015/jdv16i8p1489.pdf?request-id=8eac9396-b8ea-472f-966d-4bd66984c308

http://eprints.iisc.ernet.in/20592/

Palavras-Chave #High Voltage Engineering (merged with EE)
Tipo

Journal Article

PeerReviewed