Mitigation of distorted and unbalanced stator voltage of stand-alone doubly fed induction generators using repetitive control technique


Autoria(s): Wei, Feng; Zhang, Xinan; Vilathgamuwa, D. Mahinda; Choi, San Shing; Wang, Shuai
Data(s)

2013

Resumo

Unbalanced or non-linear loads result in distorted stator currents and electromagnetic torque pulsations in stand-alone doubly fed induction generators (DFIGs). This study proposes the use of a proportional-integral repetitive control (PIRC) scheme so as to mitigate the levels of harmonic and unbalance at the stator terminals of the DFIG. The PIRC is structurally simpler and requires much less computation than existing methods. Analysis of the PIRC operation and the methodology to determine the control parameters is included. Simulation study as well as laboratory test measurements demonstrate clearly the effectiveness of the proposed PIRC control scheme.

Identificador

http://eprints.qut.edu.au/71868/

Publicador

The Institution of Engineering and Technology

Relação

DOI:10.1049/iet-epa.2012.0317

Wei, Feng, Zhang, Xinan, Vilathgamuwa, D. Mahinda, Choi, San Shing, & Wang, Shuai (2013) Mitigation of distorted and unbalanced stator voltage of stand-alone doubly fed induction generators using repetitive control technique. IET Electric Power Applications, 7(8), pp. 654-663.

Direitos

Copyright 2013 The Institution of Engineering and Technology

Fonte

School of Electrical Engineering & Computer Science; Science & Engineering Faculty

Palavras-Chave #PI control #Asynchronous generators #Machine control #Stators #Torque #Voltage control
Tipo

Journal Article