Fire performance of LSF walls made of hollow flange section studs


Autoria(s): Sivakumar, Kesawan; Mahendran, Mahen
Data(s)

21/02/2013

Resumo

Load bearing Light Gauge Steel Frame (LSF) walls made of cold-formed steel studs and tracks are commonly used in residential and commercial buildings. Fire safety of these walls is essential to minimize the damage caused by fire related accidents. Past investigations on the fire performance of load bearing LSF wall systems have been limited to LSF walls made of conventional lipped channel section studs. Although structurally efficient hollow flange steel sections are available in the building industry, they are not used as LSF wall studs due to the lack of fire performance data for such walls. The hollow flange sections have torsionally rigid hollow flanges that eliminate the occurrence of local and distortional buckling to an extent, thereby increasing their structural efficiency. The weaknesses of hollow flange sections such as lower lateral distortional buckling capacity are also eliminated when they are used as studs of LSF walls as the plasterboard restraints will prevent any lateral movement. Therefore hollow flange sections can be considered as structurally more efficient studs for use in LSF wall systems. This paper reports the full scale fire tests of LSF walls made of hollow flange section studs under standard fire conditions. The frames were made of 1.6 mm thick and 150 mm deep hollow flange section studs with two closed rectangular flanges of 45 mm width x 15 mm depth. Dual plasterboards were attached on both sides of the test wall panels. The load ratio was varied and the failure times, the lateral deflections and the axial displacements of the test walls were obtained. The failure behaviour of LSF walls made of hollow flange section studs was found to be different to that of LSF walls made of conventional lipped channel section studs. The results of these fire tests show that hollow flange section studs have a higher potential in being used in load bearing LSF Walls.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/60665/

Relação

http://eprints.qut.edu.au/60665/1/60665.pdf

http://www.scnz.org/magazine/scnzconference_steelinnovation2013/papers/

Sivakumar, Kesawan & Mahendran, Mahen (2013) Fire performance of LSF walls made of hollow flange section studs. In Steel Innovations Conference 2013, 21-22 February 2013, Air Force Museum Conference Centre, Christchurch.

Direitos

Copyright 2013 Please consult the authors.

Fonte

Science & Engineering Faculty

Palavras-Chave #090506 Structural Engineering #FIRE PERFORMANCE #LSF WALLS #HOLLOW FLANGE SECTION #COLD-FORMED STEEL #EXPERIMENTS
Tipo

Conference Paper