Induction motor load impact on power system eigenvalue sensitivity analysis
Data(s) |
01/07/2009
|
---|---|
Resumo |
Load modelling plays an important role in power system dynamic stability assessment. One of the widely used methods in assessing load model impact on system dynamic response is parametric sensitivity analysis. A composite load model-based load sensitivity analysis framework is proposed. It enables comprehensive investigation into load modelling impacts on system stability considering the dynamic interactions between load and system dynamics. The effect of the location of individual as well as patches of composite loads in the vicinity on the sensitivity of the oscillatory modes is investigated. The impact of load composition on the overall sensitivity of the load is also investigated. |
Identificador | |
Relação |
DOI:10.1049/iet-gtd.2008.0108 Mishra, Y., Dong, Z.Y., Ma, J., & Hill, D.J. (2009) Induction motor load impact on power system eigenvalue sensitivity analysis. IET Generation, Transmission & Distribution, 3(7), pp. 690-700. |
Fonte |
School of Electrical Engineering & Computer Science; Science & Engineering Faculty |
Palavras-Chave | #090607 Power and Energy Systems Engineering (excl. Renewable Power) #dynamic response #eigenvalues and eigenfunctions #induction motors #load flow #power system dynamic stability #sensitivity analysis #composite load model #eigenvalue sensitivity analysis #induction motor load #power system dynamic stability assessment #system dynamic response |
Tipo |
Journal Article |