Investigation of 'off-line‘ relaxation phenomena in oil filled transformers


Autoria(s): Lingamaneni, Veerendra
Data(s)

2010

Resumo

Power transformers are one of the most important and costly equipment in power generation, transmission and distribution systems. Current average age of transformers in Australia is around 25 years and there is a strong economical tendency to use them up to 50 years or more. As the transformers operate, they get degraded due to different loading and environmental operating stressed conditions. In today‘s competitive energy market with the penetration of distributed energy sources, the transformers are stressed more with minimum required maintenance. The modern asset management program tries to increase the usage life time of power transformers with prognostic techniques using condition indicators. In the case of oil filled transformers, condition monitoring methods based on dissolved gas analysis, polarization studies, partial discharge studies, frequency response analysis studies to check the mechanical integrity, IR heat monitoring and other vibration monitoring techniques are in use. In the current research program, studies have been initiated to identify the degradation of insulating materials by the electrical relaxation technique known as dielectrometry. Aging leads to main degradation products like moisture and other oxidized products due to fluctuating thermal and electrical loading. By applying repetitive low frequency high voltage sine wave perturbations in the range of 100 to 200 V peak across available terminals of power transformer, the conductive and polarization parameters of insulation aging are identified. An in-house novel digital instrument is developed to record the low leakage response of repetitive polarization currents in three terminals configuration. The technique is tested with known three transformers of rating 5 kVA or more. The effects of stressing polarization voltage level, polarizing wave shapes and various terminal configurations provide characteristic aging relaxation information. By using different analyses, sensitive parameters of aging are identified and it is presented in this thesis.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/34424/

Publicador

Queensland University of Technology

Relação

http://eprints.qut.edu.au/34424/1/Veerendra_Lingamaneni_Thesis.pdf

Lingamaneni, Veerendra (2010) Investigation of 'off-line‘ relaxation phenomena in oil filled transformers. Masters by Research thesis, Queensland University of Technology.

Fonte

Faculty of Built Environment and Engineering

Palavras-Chave #oil filled transformers
Tipo

Thesis